Flexible 3-Phase Current probe 30/300/3000A ACeff

Item number: TA325

  • Flexible coils allow access to hard to reach cables and bus bars
  • High bandwidth, low noise, low phase difference/Hz
  • Suitable for connection to standard oscillosccopes with BNC sockets
  • Although not powered from the scope, the battery lasts 2000 hours
  • Category: Cables, Connectors & Adaptors


    709,00 €

    Excluding 19% VAT.

    Delivery status: ca. 1 week

    Shipping time: 2 workdays

    pc.


    Flexible 3-Phase Current Probe 30/300/3000A AC RMS

  • Flexible coils allow access to hard to reach cables and bus bars.
  • High bandwidth, low noise, low phase difference/Hz.
  • Although not powered from the scope, the battery lasts 2000 hours.


    The TA325 current probe uses the Rogowski coil principle to measure 3-phase AC currents up to 3000A, without suffering from saturation. This probe has flexible sensor coils, enabling you to measure currents on conductors that clamp-type curent probes just can't get to, while the long battery life means you can leave it conected for longer-term measurements.

    The probe is fitted with  BNC connectors, so you will need to use three TA271 single-ended  D9-BNC adaptors to connect it to the PicoScope 4444. The probe is not powered or sensed by PicoScope 4444 and can also be used with other oscilloscopes which have BNC inputs.

    The TA325 is a switched-range 30/300/3000A AC RMS probe with 10Hz to 20kHz bandwidth, rated to 1000V CAT III on uninsulated conductors. Suitable for measuring 3-phase AC current, it has three sensor coils and scope connection leads, colour-coded to match channels A, B and C in the PicoScope software. Typical battery life is 2000 hours.


    The TA325 probe is supplied without the depicted PicoScope 4444 and without the TA271 adaptors.

    Technical data:
    Measuring ranges: 30/300/3000A AC
    Output sensitivity: 100/10/1mV per A (AC coupled)
    Accuracy (45-65Hz): ± 1% of reading ± 0.1A 30/300A
                                     ± 1% of reading ± 1 A 3000A
    Minimum load: 100kOhm for specified accuracy
    Frequency range: 10Hz to 20kHz (-1dB)
    Phase (45-65Hz): <±1°
    Position sensitivity: ± 2% of reading
    Noise: 80mA RMS  30A
               400mA RMS 300/3000A
    Temperature coeff.: ± 0.1% /°C
    Power supply: two AA MN1500 LR6 alkaline batteries or an external power supply (+3V/100mA)
    Battery life: 1000 hours typical
    External Power: via 2.1 mm (0.08") mini power connector
    Low battery: indicated by an orange LED
    Overload: indicated by a red LED
    Housing material: ARNITE T06-200SNF, UL94 V0
    Degree of protection: IP40
    Dimensions: 110 x 65 x 23mm³ (L x W x D)
    Output connection: 0.5m coax cable with 3 shrouded BNC connectors

    Probe:
    Probe length: 610mm (24”), double-insulated
    Probe diameter: 9.9mm (0.39”)
    Output cable: 2m (78.7”), probe to integrator
    Degree of Protection: IP65

    General Characteristics:
    Operating temp.: -20°C to +65°C (-4°F to +149°F)
    Storage temp.: -40°C to +75°C (-40°F to +167°F)
    Operating humidity: 15% to 85% RH (non-condensing)
    Safety standards: EN 61010-1, EN 61010-2-032,
    EMC:  EN 61326-2-2
    1000V RMS, Category III, 600V RMS, Category IV
    30V maximum between output and ground
    Rated for continuous use.

  • Average product review